Normes IEC

Compléments des normes (Clarification sheets, decisions sheets, etc…)

IEC 60079-0:2017  Part 0: Equipment – General requirements
IEC 60079-1:2014  Part 1: Equipment protection by flameproof enclosures « d »
IEC 60079-2:2014  Part 2: Equipment protection by pressurized enclosure « p »
IEC 60079-5:2015  Part 5: Equipment protection by powder filling « q »
IEC 60079-6:2015+AMD1:2020  Part 6: Equipment protection by liquid immersion « o »
IEC 60079-7:2015+AMD1:2017  Part 7: Equipment protection by increased safety « e »
IEC 60079-10-1:2015  Part 10-1: Classification of areas – Explosive gas atmospheres
IEC 60079-10-2:2015  Part 10-2: Classification of areas – Explosive dust atmospheres
IEC 60079-11:2011  Part 11: Equipment protection by intrinsic safety « i »
IEC 60079-13:2017  Part 13: Equipment protection by pressurized room « p » and artificially ventilated room « v »
IEC 60079-14:2013  Part 14: Electrical installations design, selection and erection
IEC 60079-15:2017  Part 15: Equipment protection by type of protection « n »
IEC TR 60079-16:1990  Part 16: Artificial ventilation for the protection of analyser(s) houses
IEC 60079-17:2013  Part 17: Electrical installations inspection and maintenance
IEC 60079-18:2014+AMD1:2017  Part 18: Equipment protection by encapsulation « m »
IEC 60079-19:2019  Part 19: Equipment repair, overhaul and reclamation
IEC 60079-25:2020  Part 25: Intrinsically safe electrical systems
IEC 60079-26:2014  Part 26: Equipment with Equipment Protection Level (EPL) Ga
IEC 60079-28:2015  Part 28: Protection of equipment and transmission systems using optical radiation
IEC 60079-29-1:2016+AMD1:2020  Part 29-1: Gas detectors – Performance requirements of detectors for flammable gases
IEC 60079-29-2:2015  Part 29-2: Gas detectors – Selection, installation, use and maintenance of detectors for flammable gases and oxygen
IEC 60079-29-3:2014  Part 29-3: Gas detectors – Guidance on functional safety of fixed gas detection systems
IEC 60079-29-4:2009  Part 29-4: Gas detectors – Performance requirements of open path detectors for flammable gases
IEC/IEEE 60079-30-1:2015  Part 30-1: Electrical resistance trace heating – General and testing requirements
IEC/IEEE 60079-30-2:2015  Part 30-2: Electrical resistance trace heating – Application guide for design, installation and maintenance
IEC 60079-31:2013  Part 31: Equipment dust ignition protection by enclosure « t »
IEC TS 60079-32-1:2013+AMD1:2017  Part 32-1: Electrostatic hazards – guidance
IEC 60079-32-2:2015  Part 32-2: Electrostatics hazards – Tests
IEC 60079-33:2012  Part 33: Equipment protection by special protection ‘s’
IEC 60079-35-1:2011  Part 35-1: Caplights for use in mines susceptible to firedamp – General requirements – Construction and testing in relation to the risk of explosion
IEC 60079-35-2:2011  Part 35-2: Caplights for use in mines susceptible to firedamp – Performance and other safety-related matters
IEC TS 60079-39:2015  Part 39: Intrinsically safe systems with electronically controlled spark duration limitation
IEC TS 60079-40:2015  Part 40: Requirements for process sealing between flammable process fluids and electrical systems
IEC TS 60079-42:2019  Part 42: Electrical safety devices for the control of potential ignition sources for Ex-Equipment
IEC TS 60079-43:2017  Part 43: Equipment in adverse service conditions
IEC TS 60079-46:2017  Part 46: Equipment assemblies
ISO/IEC 80079-20-1:2017  Part 20-1: Material characteristics for gas and vapour classification – Test methods and data
ISO/IEC 80079-20-2:2016  Part 20-2: Material characteristics – Combustible dusts test methods
ISO/IEC 80079-34:2018  Part 34: Application of quality management systems for Ex Product manufacture
ISO/IEC 80079-38:2016  Part 38: Equipment and components in explosive atmospheres in underground mines
ISO 80079-36:2016  Part 36: Non-electrical equipment for Basic method and requirements
ISO 80079-37:2016  Part 37: Non-electrical equipment for Non electrical type of protection constructional safety « c », control of ignition source « b », liquid immersion « k »

Normes Amérique du nord

Pour obtenir une certification en vue de commercialiser un matériel à destination d’atmosphères explosibles en amérique du nord, le fabricant devra se mettre en conformité avec deux composants normatif majeurs:

Le National Electrical Code (NEC – NFPA 70) pour les USA & Le Canadian Electrical code (CEC part 1 – CSA 22.1) pour le Canada

Ces deux documents couvrent l’ensemble des exigences pour les équipements électriques et comportent tous deux un passage spécifiques aux atmosphères explosibles:

Les paragraphes 500, 503, 505, et 506 pour le NEC et la section 18 pour le CEC.

La certification pour l’amérique du nord pour les atmosphères explosibles (Hazlocs) implique au préalable la conformité de l’installation électrique pour un environnement non explosif.

Ainsi pour une installation complète, le fabricant devra souvent se conformé aux exigences associées à un panneau de contrôle (UL508) pour les USA et CSA C22.2 NO 14 pour le Canada)

Voici un résumé des bases normatives à prendre en compte en vue de la mise sur le marché américain d’un équipement à destination des atmosphères explosibles. Mais le processus est assez complexe et l’assistance d’ATEXELEC est fortement recommandée pour assurer votre succès.